1. Issue Description
There is no handover signal between two H2000 eNodeBs. It only shows handover preparation failture when disable the adminstate manually.
Source node: .31
Target node:.32
2. Troubleshooting procedure
2.1 Configuration check
Measurement and neighbour configuration is confirmed fine.
2.2 clock synchronization check
The current synmode Source node is GPS and the neighbour eNodeB is freerun. There is 2 hours time gap.
3. Solution
Modify the “Syncmode” from freerun to GPS and enable the switch “SyncSwitchEnable”.
Make sure the GPS clcok status is success after modify the clcok mode and reboot.
Handover Test Success: