Q1: How To Query Encryption and Integrity Switch ?
A: Query by Signal Messages
Q2: How Turn off Encryption and Integrity Switch ?
A: Turn on and off by odi commands
① odi -n cpcellapp0 fto-set-security-mod-enable 1703939 1
② odi -n cpcellapp0 fto-set-integrity-ue-enable 1703939 0
③odi -n cpcellapp0 fto-set-cipher-ue-enable 1703939 0
Note: cpcellapp0 indicates Cell ID 1, 1703939 indicates NRCellID, 1 indicates switch turns on, 0 indicates switch turns off.
Commands Combination For Different Function:
①1-②0: Indicates Integrity off, encryption off.
①1-②0-③0: Indicates Integrity off, encryption off.
①1-②1-③0: Indicates Integrity on, encryption off.
①1-②0-③1: Indicates Integrity off, encryption on.
Please refer to the document for the detailed procedures and download the documentations: