Category | OAM |
Issue Description | BBU keeps restarting itself |
Analysis | Possible reasons
|
Solution |
If we found SSH could be logged in stably and Phy Printing shows abnormal, normally the issue is caused by the Self-protection mechanism of BBU. With the command below can kill the mechanism temporally. killall -9 monProcess After modifying the parameters to bring the cell up, the cycle auto restart issue of BBU can be solved. |